Product Highlights
The PPC-1B’s non-volatile display memory ensures that accumulated counts are not lost if power is interrupted during a test — a critical advantage in field environments where the 12VDC supply may be disconnected and reconnected. The counter can be manually reset by the technician at any time, making it straightforward to start a new count without returning to a base or office.
Its Form A configuration makes it practical for quickly checking whether either the KY or KZ side of a Form C output is pulsing correctly — identifying which side of the output may be faulty without requiring additional test equipment.
Features
- 8-digit non-volatile display — maximum count of 99,999,999; count retained through power interruptions.
- Form A (2-wire) input — tests one side of Form C output at a time; compatible with mercury-wetted, electromechanical, and solid-state relay outputs.
- Built-in 12VDC wetting voltage — supplies sense voltage to the meter's Y output; no external supply required.
- Manual reset — field technician can reset the counter at any time without tools or software.
- 12VDC wall power supply — included with unit; no batteries required.
- Rotatable cover — rotates 90, 180, or 270 degrees to orient input jacks in the preferred position for the application.
- Rugged NORYL enclosure — built for field durability; 4.00" x 4.00" x 2.25" footprint.


Portable KYZ Field Pulse Counter
Can't Find What You're Looking For?