RS-933 Syntron Automated Calibration System

Features:Contact Rep.Contact Rep.

Testing Efficiency

Automated results calculation, automated saving of data, unattended testing capabilities, and the ability to test up to 16 meters at one time will reduce test times from days to hours.

Simple Operation

While sophisticated in its internal functioning, the RS-933 system is very simple to operate.  The system was designed so that a new user could be up and running after a brief training session.

Testing Standardization

Utilizing Radian’s patented Syntron technology, the RS-933 serves as a sourcing standard by synthesizing voltage and current waveforms of extreme precision and accuracy. Traceability of the RS-933’s measurement accuracy is maintained directly through Radian’s NIST traceable calibration laboratory.

Expansive Testing Capabilities

The RD-933 test various devices such as Reference Standards, Digital Multimeters, Phase meter, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters and Power Quality meters with extreme accuracy and precision.

The RS-933 with RD-22 Provide a Complete Automated Reference System

The RS-933 and RD-22 working together effectively serve as a check and balance to the proper functioning of the test sequence. In addition, primary references of DC Voltage, Resistance and Time can be tested against the RD-22. This is a useful feature for those laboratories that desire to perform a DC to AC transfer.

OverviewContact Rep.Contact Rep.

Overview

The RS-933 automated energy calibration system calibrates a range of test equipment including; Energy Reference Standards, Digital Multimeters, Phase meters, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters & Power Quality meters.

Its ability to deliver 1mA to 200A from one single output offers a versatile solution that reduces test time by eliminating the need to reconfigure test leads. Radian’s direct drive current output technology improves stability, repeatability and settling time without the need for measurement feedback found on older equipment.

The system achieves a guaranteed accuracy of 50 ppm, this delivers a superior calibration solution to address a broad range of workload.

The RS-933 has the ability to create user defined waveforms.  Independent Voltage and Current harmonics relative to the fundamental are established using the software provided.

The system automatically tests up to 16 meters simultaneously maximizing throughput and reducing labor costs.

For meter qualification applications, the system’s ability to deliver signals that help determine cross talk, drift and harmonic distortion simplifies and reduces test time.

With over 36 energy parameters including, multiple VARhours, the versatility of the RS-933 delivers a wide choice of functions necessary to meet today’s laboratory calibration requirements.

With increasing demand for ‘real world’ simulation the  system provides the flexibility to choose single or multiple phases with harmonic control of each independent phase and axis.

The RS-933 software provides full automation and documentation control. The familiarity of the Microsoft Windows based solution shortens integration time and reduces training needs.

System efficiency is further enhanced using TCP/IP interface protocol making control and data access available from your company network. This control allows test data to be accessed at any local or remote terminal.

The RS-933 is based on Radian's proven Syntron technology, continual development offers unparalleled performance across a wide range of functions.

Routine verification and system traceability can be achieved using the Radian RD-22 AC/DC transfer standard. Preprogrammed calibration routines within the software offer a simple but unique solution to reducing system downtime and costly maintenance.

A dedicated 20 MHz Reference Clock pulse output offers external measurement system synchronization. Furthermore, the system is able to synchronize to an external GPS Frequency Standard. The 1 pps external signal can be routed to any of the data outputs enabling simplified UUT time/frequency calibration.

Technical DataContact Rep.Contact Rep.

 

New System Configurations

Model Number New System Configuration Description
931/8C/120A Single phase, 8 channel data collection, 120amp
933/8C/120A Three phase, 8 channel data collection, 120 amp
931/8C/200A Single phase, 8 channel data collection, 200 amp
933/8C/200A Three phase, 8 channel data collection, 200 amp
931/16C/120A Single phase, 16 channel data collection, 120amp
933/16C/120A Three phase, 16 channel data collection, 120 amp
931/16C/200A Single phase, 16 channel data collection, 200 amp
933/16C/200A Three phase, 16 channel data collection, 200 amp

System Specifications

Accuracy

Power: ±0.005 %, Voltage: ±0.0043 %, Current: ±0.0063 %, Phase: ±0.003°
Traceability to NIST for fundamental waveforms
This accuracy specification is listed as Percent of Reading and applies across the entire voltage and current range and within a temperature operating range of 23° C + 5° C. Accuracy also includes stability, power factor and test system error.

Temperature Coefficient Power = 1 ppm/° C
Power Requirements 240 VAC, 30 A
Supply Frequency 48-62 Hz
Output Range:  
      Voltage

60-630 V  at 60Hz, 60-525 V at 50 Hz [(10.5)*(F) not to exceed 630V]
(0.001 volt increments) (V < 60 V is at linearly derated accuracy)
Vout is 150 VA per phase at 120V or higher.

      Current 1mA to 200 A
      Frequency 47-68 Hz (Fundamental)
      Phase Angle 0-360 degrees (0.00001 degree increments)
Stability Under Typical Load Power: ±0.0035%, Voltage: ±0.0032%, Current: ±0.0044%
Pulse Constant Range of UUT 1x10-11 to 9x10+11
Pulse Input Voltage High: >+1.6 V, Voltage Low: <+1.4 V, Maximum Frequency: <4MHz, Minimum Frequency: 2 microHertz
Recalibration Interval 365 days

Physical Description

Size (63") H x (47.0") W x (25.5") D
Base System Weight (775 lbs)
Shipping Dimensions Same as overall dimensions (freight shipment)

Upgrade System Configurations

Model Number Booster Upgrade Only Description
703/1P/UPG/120 BOOST Single phase boost module, 120 amp
703/1P/UPG/200 BOOST           Single phase boost module, 200 amp
703/3P/UPG/120 BOOST           Three phase boost module, 120 amp
703/3P/UPG/200 BOOST           Three phase boost module, 200 amp
Model Number Data Collection Upgrade Only Description
UPG93X/16C DATA 16 channel data collection module
Model Number RS-600 System Upgrade Description
600UPG/931/16C/120 Single phase, 16 channel data collection,120 amp
600UPG/931/16C/200 Single phase, 16 channel data collection,200 amp
600UPG/933/16C/120 Three phase, 16 channel data collection,120 amp
600UPG/933/16C/200 Three phase, 16 channel data collection,200 amp
Model Number RS-703A Single Phase System Upgrade Description
703/1P/UPG/931/16C/120 Single phase, 16 channel data collection,120 amp
703/1P/UPG/931/16C/200 Single phase, 16 channel data collection,200 amp
703/1P/UPG/933/16C/120 Three phase, 16 channel data collection,120 amp
703/1P/UPG/933/16C/200 Three phase, 16 channel data collection,200 amp
Model Number RS-703A Three Phase System Upgrade Description
703/3P/UPG/933/16C/120 Three phase, 16 channel data collection,120 amp
703/3P/UPG/933/16C/200 Three phase, 16 channel data collection,200 amp

AccessoriesContact Rep.Contact Rep.

 

RD-22

Primary Transfer Standard

 

RM-OA

Optical Adapter

 

RR-1H

Optical Pickup

 

RM-KYZ

Remote Portable Printer

   

RM-1B

Signal Converter

 

RM-DS

Disk Sensor